Thursday, July 12, 2012

Electrical Fire

What Is An Electrical Fire?


The public has not been encouraged to distinguish fire danger arising from electrically powered things (or their abuse) from fire danger arising out of imperfections in an electrical system (due to design or installation). Fires from this second matter certainly deserve the name "electrical", though it must still be understood that any fire that is destructive beyond the malfunctioning electrical system equipment itself (destructive, that is, of people or belongings) is actually a structural fire, which depends on the proximity of combustibles to such electrical equipment.
By this definition, for example, fires originating from light fixtures that overheat from bulbs of excessive wattage are not electrical. Nor is a fire from bedding blocking the airflow of an electric heater (unless the heater’s safety device failed to shut it down). Also an arcing short from someone’s having nailed a cord along the surface of a wall would not be an "electrical" fire as I am defining it. Rather, this would be a case of abuse of an electrical appliance, not a case of improper installation of the electrical distribution system.
It could be that over an indefinitely long time, every electrical component installed in every home could deteriorate to the point of presenting a slight fire hazard. The design, approval, and installation of these components does not take into consideration such a long period of time, during which many kinds of conditions can have an effect on their integrity. Nor could there be an economical way of requiring such longevity from the beginning. We assume the need for some maintenance and for eventual replacement -- even of the building itself. Whether the maintenance done is preventive or is in response to problems encountered might make some difference in fire statistics, but this has not been shown, that I am aware of. Over-maintenance is possible. Also, since any change made can awaken existing imperfections or contain imperfections of its own, total safety will never be a realistic goal.

Of all home fires 1994-1998, about 3%* were due to electrical system failures, as I have defined them, compared with 2% from natural causes. I admit my definition is that of an electrician (who is also apologizing for problems with the design and manufacture of the components I install) and I hope that my conscientiousness in installation counteracts the negligence of a few other electricians. I sympathize with some of the distrust the public has developed for electrical things in general, but not all of it, because this has been an area of considerable hype.

Reference for photo A thru L:

A. This smallest object on the page, tucked next to a receptacle with push-in wire receivers (B), comes first on my list because it shows the most common connection malfunction. The others items are more dramatic visually, but you can barely see the dark spot not far from the end of this piece of aluminum wire. That spot it where a receptacle similar to B was holding wire A by means of springy receivers, which bit into the soft aluminum. So the amount of pressure on the wire at that point was not as much as the receptacle was designed to give (designed, namely, for copper only). In addition, the aluminum and the brass alloy of the receiver will corrode somewhat when in contact with each other, especially under conditions of current and the heat it produces. The dark spot was mostly created by the extreme heat of current arcing past the deteriorated or depressurized metal-to-metal contact point. Copper will often show this problem too. In the case of copper, pressure may be adequate, but poor contact can still be from surface oxidation on the copper or simply from the surface area designed for the contact being too small to sustain varieties of current in varieties of temperature and humidity over the years. Some people speak of wires working their way loose from current's heat expanding and contracting them. I think this could be confirmed for connections being held by screws. In the case of these push-in type, I think it is sometimes due to careless installation, including putting too much stress on the receivers and "despringing" them. As I say, these minor looking arc points toward the bare wire-end are the most common cause of both partial circuit outages and the flickering that often precedes them.

B. This push-in style receptacle (see A above) is shown from its back side. The darkness around the push-in holes tells us that heat had developed at both "hot" and neutral wire connection points. This is not very common, but we can imagine that the heat starting on one side can hasten metal-surface deterioration on the other.

C. The "hot" side of these two receptacles did get hot. Both were using screw terminals to hold their aluminum wires. The plastic of the one on the left suffered so much that the screws and metal plug-receivers that were usually held captive pulled right out. The one on the right is a fairly new receptacle used to replace an older one, but since the wires were aluminum, which don't get along well with the alloys of most receptacles, these connections didn't last long. Only receptacles that say CO/ALR (copper/aluminum rated) are able to connect aluminum wires directly to their terminals.

D. These two aluminum-wired receptacles suffered their heat on the neutral side. True, their wires don't look white like neutrals should, but they were at one time. The insulation on the wires of the left hand receptacle melted and vaporized back about two inches from the source of the heat (the screws). In my experience three inches is as far as I see things go. By that time the connection has gotten so poor it doesn't let current flow through it anymore. So the heating process is self-defeating -- usually. Under some conditions, the heat does reach and ignite combustible materials; I am not called to these cases, firemen are. See What is an electrical fire.

E. With these two receptacles we are back to trouble on the "hot" side, but now it is copper wire. What caused the copper connections to go bad? I know of two common reasons. One is that the person installing did not seat the loop of copper evenly and directly under the screw, did not tighten the screw enough, or curled the copper counterclockwise under the screw (so that tightening actually squeezed the loop apart and outward). The other reason is similar -- the installer was not careful to insure that only metal ended up trapped under the screw. When the loop under the screw includes any insulation, the screw cannot be holding the metal as tightly as it should, even though it feels tight. One reason people do this by accident is that they are replacing receptacles in the home that had the wires connected push-in style in the back. They are going to improve things by having their new receptacles connected with the more reliable screws. Trouble is, the push-in wires never needed to have their insulation stripped back very far to do their job, but few of these have enough length for a full loop that will be held under the screw without catching some insulation under it. Strip more off before putting them under screws.

F. Here copper had a poor connection on the neutral side.

G. These are the ends of three neutral wires. I don't recall whether they had been attached to receptacles or whether the poor contact was in a wire connector ("wirenut").

H. Likewise, here are two "hot" wires that led dysfunctional lives.

I. The discoloration of this receptacle at one of its straight slots is typical of poor pressure being given by the receptacle's receivers on the prongs plugged into them. Many people are aware of receptacles in their homes that do not hold on strongly. When this is so, heat can develop there, especially for heavier watt-users. The receivers get sprung loose this way by repeated plugging in and out, and more so when a cord is pulled out a bit sideways, as when a vacuumer has gone too far afield. Receptacles with this kind of appearance should be replaced. The kind of arcing that can go on when a plug is gradually falling out while still running a lamp, has been known to start fires and is the kind of hazard which arc-fault interrupters are supposed to prevent.

J. This monstrosity is a clothes dryer cord-plug (on the left) and what is left of one receiver (on the right) of that dryer's receptacle. Though signs of heat are evident on everything here, the source was the receiver being sprung apart too far. Maybe sometime in the past someone moved the dryer too far while it was still plugged in. This is the same situation as I just described above in "I", but on a 240-volt 30-amp scale.

K. This is the socket of a common porch light. The heat it suffered was not from a poor connection, the way everything described above was. It was from running 75- or 100-watt bulbs in a fixture that was only designed to dissipate the heat of a 60-watt bulb. The result is the same: the thing stopped working. But it might have shorted its whole circuit out first.

L. This chunk of underground cable was shorting its circuit down in the ground, helped by water and soil, but started by a shovel's nick. This too is not a case of heat from a poor connection, but I wanted to show that there are other ways wires can get looking ugly. I find that an underground cable like this one doesn't short into the actual earth significantly -- it is enabled to short from its exposed hot over to its own ground wire, by the conductivity of the moisture and soil that is right along the surface of the cable.https://www.facebook.com/pages/All-Tech-Electric-Contracting/276520805731211

Sunday, July 8, 2012

landscape lighting

Installing Landscape Lighting

  • When installing electrical power that will be used for outdoor devices the circuit should always be protected by a GFCI Ground Fault Circuit Interrupter.
  • If a light fixture will be submerged then the fixture should be rated as such.
  • When installing electrical devices within proximity of swimming pools then there are several NEC Codes that would have to be addressed, as you have seen this stated on the fixtures that have been purchased.
  • As you have stated and because of the location of the pool and the lighting, this landscape lighting project may be best turned over to a local electrical contractor who can see the complete project and make the best recommendations and installation.
  • A Master Electrician will have the greatest expertise on  necessary equipment, function, and istallation
  • www.kansa-electrician.com

'like' us on Facebook:  "Kansas Electrician" and "All Tech Electric & Contracting"

Power is out in part of my home....

Electrical Question: Part of my house power is out. I checked outlets and no power was found. I went to the breaker box and tested power coming out of each breaker and found that every other one had power and and every other one didn’t have power. This included testing the 4 breaker main switches, which 2 of the 4 had power and 2 didn’t. So I removed them from the panel and ohm tested them. 2 seemed to work properly( open then switch to closed) 2 showed very little chance or difference which ever position the switch was in. So I switched the wires from one to the other and different power worked. So it seems the breakers are bad. However this seems very strange to me that the would go bad. The whole panel and breakers are only 8 yrs old. Any thoughts or further ideas would be great.

Electrical Panel and Circuit Testing

  • There are a few conditions that may cause half of the power to not work in a home. Some brands of electrical panels are prone to having failures especially in the summer time when electrical loads are high which causes problem due to expansion and contraction with electrical parts which could lead to a deteriorated connection, which then causes arcing, which can then lead to damaged electrical components and the loss of electrical power to part or all of the electrical service.
  • Main circuit breakers may trip into the OFF position, and sometimes only half of the 240 volt power will trip OFF while the other phase of power remains in the ON position. This can be caused by circuit over load or other circuit problems.
  • Main circuit breakers may fail as well causing the same condition where half of the power is lost while half remains ON.
  • Before considering replacing circuit breakers it is best to have the condition thoroughly tested by a qualified licenses electrical contractor as it is not recommended that a homeowner perform work in an electrical panel.

Saturday, July 7, 2012

Hire an Electrician- Problems with Electrical Circuts

Electrical Question about Problems With Electrical Circuits


thumbnail5.jpg
Question: I have been having a problem when I run the vacuum and plug it in on the west side of my condo, the west side power goes out but then comes back on (by itself) after 5-10 seconds (which I never heard of). I worked around this by plugging it in on the east side of the condo since the cord reaches…problem solved. Well, now with the heat, i have been using my portable A/C and experienced the same thing…I cannot use an extension cord for that plus it must be near the door so I can use the exhaust portal. Now today I came home from work, did not leave anything on except the fridge, oven/stove and microwave…also the TV & DVR were plugged in but turned off. When I got home, everything was off, then a few seconds and it would try to come back on and turn off again like the circuit breaker was auto-resetting. I went in the guest bedroom and their was no noise at the circuit breaker panel when the East side would come off and immediately turn off. I unplugged every single thing including the fridge, microwave, oven & all lamps, no power at all being used on the east side including nightlights. i turned on the stove and same thing, was hoping that was my problem…unplugged the stove and plugged in the microwave above it, worked fine…unplugged the microwave and plugged in the fridge, power went out…unplugged the fridge and turned on the surge protector for the TV/DVD and power went out. And again, the items would shut down then restart after 10 seconds then shut down almost immediately then restart. Any ideas? This is a multi-unit condo, I am on the 3rd floor. I have never lived anywhere where the power will go out then come back on.


Additional Comments: Great website!





Reply:

Thanks for your electrical question.
This sounds like a connection problem at the electrical panel with one of the main incoming electrical lines, most likely the neutral, or it could be a main circuit breaker that has a deteriorating connection with an internal panel component.
This is a very common electrical problem that occurs when the outside temperatures rise which will cause the electrical loads (air conditioning, etc.) to increase, thereby causing expansion and contraction of the electrical components, especially those components which are aluminum type materials and or aluminum wire.
This electrical problem will require testing and troubleshooting starting at the electrical panel that feeds your home electrical circuits. This is a problem that requires an experienced qualified licensed electrician.

Kitchen Electrical Code Requirements

Kitchen Electrical Code Requirements and Energy Efficient Specifications

Kitchen Wiring Diagram LightsOne half of the kitchen lighting wattage must be High Efficiency (fluorescent or equivalent) and switched separately from other lights.
wirig diagram kitchen gfciKitchen countertops, including islands wider than 12 inches, and any usable spaces wider than 2 feet, shall be provided with an electrical outlet at 48" on center. GFCI protection is required for these outlets.
Kitchen 20 Amp Appliance CircuitsProvide a minimum of 2 - 20 amp electric circuits for kitchen appliances.
Kitchen Counter Appliance CircuitProvide 2 small-appliance branch circuits for outlets in the kitchen limited to supplying wall and counter space outlets only.
wiring diagram kitchen plugs A GFCI is required for all 120 volt receptacles installed for the electrical wiring at kitchen countertops and within 6-feet of sinks.
Wiring Diagram Range ReceptacleThe home electrical wiring for kitchens requires that you provide a 4-wire oven receptacle for electric an range.