“Should I upgrade the electrical service?” is a question homeowners ask frequently. An upgrade of an electrical service typically involves an older residence with service size of 100 amps or less and the homeowner is deciding whether to increase the amperage to 200.
It wasn’t until the 1960’s that circuit breakers became the standard for electrical service panels - before that all electrical panel...s contained screw and cartridge type fuses.
The way an electrical panel is made is the same regardless whether the panel uses fuses or circuit breakers. Fuses have taken a bad rap only because of the ease in which a fuse of one size can be replaced with a larger fuse. For example if a 15 amp fuse blows frequently a 20 amp fuse can be used to eliminate the nuisance of having to change the fuse so often. When a 20 amp fuse is inserted where a 15 amp was the current carrying capacity of the circuit is increased by 33% without any regard to the wire size. Remember that the fuse is rated according to the wire size – that is worth repeating a little louder – THE FUSE IS RATED ACCORDING TO THE WIRE SIZE. Because is it so easy to insert a 20 or even 30 amp fuse in to a 15 amp circuit, fuse panels have become an electrical hazard.
When a house is inspected for resale many insurance companies require a fuse panel to be replaced by a circuit breaker panel before the sale is complete. If the current service contains fuses it is probably worth the investment to upgrade the service from fuses to circuit breakers.
Upgrading the service to circuit breakers does not mean the amperage has to be increased. It is OK to change out a 100 amp fuse panel with a 100 amp circuit breaker panel. Just because the service is changing to circuit breakers does not mean the amperage coming in to the house must be increased to 200 amps.
It wasn’t until the 1960’s that circuit breakers became the standard for electrical service panels - before that all electrical panel...s contained screw and cartridge type fuses.
The way an electrical panel is made is the same regardless whether the panel uses fuses or circuit breakers. Fuses have taken a bad rap only because of the ease in which a fuse of one size can be replaced with a larger fuse. For example if a 15 amp fuse blows frequently a 20 amp fuse can be used to eliminate the nuisance of having to change the fuse so often. When a 20 amp fuse is inserted where a 15 amp was the current carrying capacity of the circuit is increased by 33% without any regard to the wire size. Remember that the fuse is rated according to the wire size – that is worth repeating a little louder – THE FUSE IS RATED ACCORDING TO THE WIRE SIZE. Because is it so easy to insert a 20 or even 30 amp fuse in to a 15 amp circuit, fuse panels have become an electrical hazard.
When a house is inspected for resale many insurance companies require a fuse panel to be replaced by a circuit breaker panel before the sale is complete. If the current service contains fuses it is probably worth the investment to upgrade the service from fuses to circuit breakers.
Upgrading the service to circuit breakers does not mean the amperage has to be increased. It is OK to change out a 100 amp fuse panel with a 100 amp circuit breaker panel. Just because the service is changing to circuit breakers does not mean the amperage coming in to the house must be increased to 200 amps.
No comments:
Post a Comment